详细信息

Ethanol
UV-method
for the determination of ethanol in foodstuffs and other
materials
Simplified procedure for the determination of ethanol
in alcoholic beverages: see pt. 13
BOEHRINGER MANNHEIM / R-BIOPHARM
Enzymatic BioAnalysis / Food Analysis
For use in in vitro only Store at 2-8°C
For recommendations for methods and standardized procedures see
references (2)
Cat. No. 0 176 290
Test-Combination for approx. 30 determinations
Principle (Ref. 1)
Ethanol is oxidized to acetaldehyde by nicotinamide-adenine dinucleotide
(NAD) in the presence of the enzyme alcohol dehydrogenase (ADH) (1).
The equilibrium of this reaction lies on the side of ethanol and NAD. It can
be completely displaced to the right side at alkaline conditions and by trapping
of the acetaldehyde formed. Acetaldehyde is quantitatively oxidized to
acetic acid in the presence of aldehyde dehydrogenase (AI-DH) (2).
NADH is determined by means of its light absorbance at 334, 340 or 365 nm.
The Test-Combination contains
1. Bottle 1 with approx. 100 ml of solution, consisting of:
potassium diphosphate buffer, pH approx. 9.0
2. Bottle 2 with approx. 30 tablets, each tablet contains:
NAD, approx. 4 mg; aldehyde dehydrogenase, approx. 0.8 U
3. Bottle 3 with approx. 1.6 ml suspension, consisting of:
ADH, approx. 7000 U
4. Ethanol assay control solution for assay control purposes (measurement
of the assay control solution is not necessary for calculating the results.)
Use the assay control solution undiluted. (Expiry date: see pack label)
Preparation of solutions
1. Use contents of bottle 1 undiluted.
2. Dissolve one tablet of bottle 2 with 3 ml solution of bottle 1 in a beaker
 or in a centrifuge tube for each assay (blank or samples) depending on
the number of determinations. Use forceps for taking the tablets out of
bottle 2. This results in reaction mixture 2*.
3. Use contents of bottle 3 undiluted.
Stability of reagents
Solution 1 is stable at 2-8°C (see pack label).
Bring solution 1 to 20°C before use.
The contents of bottle 2 are stable at 2-8°C (see pack label).
Reaction mixture 2 is stable for one day at 2-8°C.
Bring reaction mixture 2 to 20°C before use.
The contents of bottle 3 are stable at 2-8°C (see pack label).
Procedure
Wavelength1: 340 nm, Hg 365 nm or Hg 334 nm
Glass cuvette2: 1.00 cm light path
Temperature: 20°C
Final volume: 3.150 ml
Read against air (without a cuvette in the light path), against water or
against blank3
Sample solution: 0.3-12 μg ethanol/assay4 (in 0.100-0.500 ml sample
volume)
1 The absorption maximum of NADH is at 340 nm. On spectrophotometers, measurements
are taken at the absorption maximum; if spectralline photometers equipped with a mercury
vapor lamp are used, measurements are taken at a wavelength of 365 nm or 334 nm.
2 If desired, disposable cuvettes may be used instead of glass cuvettes.
3 For example, when using a double-beam photometer.
4 See instructions for performance of assay
5 Amtliche Sammlung von Untersuchungsverfahren nach §35 LMBG; Untersuchung von
Lebensmitteln: Ermittlung des Ethanolgehaltes in Alkohol und alkoholhaltigen Erzeugnissen
aller Art (ausser Wein und Bier), L 37.00-1 (Nov. 1982). See also Reference 3.9, page
783. For corrections for the effect of temperature see e.g. Official Journal of the European
Communities L 272 (3 October 1990), Legislation, Commission Regulation (EEC) No 2676/
90 of 17 September 1990 determining Community methods for the analysis of wines.
(1) Ethanol + NAD+
ADH
acetaldehyde + NADH + H+
(2) Acetaldehyde + NAD+ + H2O AI-DH acetic acid + NADH + H+
It is absolutely necessary to stopper the cuvettes, e.g., with Parafilm, during
measurement (see "Instructions for performance of assay") in order to prevent
the assay mixture form adsorption of ethanol from air.
* For simplification of the assay performance it is also possible to pipette directly 3.000 ml of
solution 1 into the cuvette. Afterwards add 1 tablet from bottle 2 and dissolve it (for solubilization
crush the tablet with a glass rod or a plastiv spatula). Continue as described in the
scheme. The volume error of approx. 1% (the increase of volume caused by one tablet/3.150
ml final volume) has to be taken into account in the calculation by multiplication of the
result with 1.01.
** Rinse the enzyme pipette or the pipette tip of the piston pipette with sample solution before
dispensing the sample solution; pipette sample solution always under the surface of the
reaction mixture 2.
*** For example, with a plastic spatula or by gentle swirling after closing the cuvette with
Parafilm (trademark of the American Can Company, Greenwich, Ct., USA)
Determine the absorbance differences (A2-A1) for both, blank and sample.
Subtract the absorbance difference of the blank from the absorbance
difference of the sample.
The measured absorbance differences should, as a rule, be at least 0.100
absorbance units to achieve sufficiently precise results (see "Instructions for
performance of assay" and “Sensitivity and detection limit”, pt.4).
Calculation
According to the general equation for calculating the concentration in
reactions in which the amount of NADH formed is stoichiometric to half the
amount of substrate:
V = final volume [ml]
v = sample volume [ml]
MW = molecular weight of the substance to be assayed [g/mol]
d = light path [cm]
ε = extinction coefficient of NADH at:
340 nm = 6.3 [l × mmol-1 × cm-1]
Hg 365 nm = 3.4 [l × mmol-1 × cm-1]
Hg 334 nm = 6.18 [l × mmol-1 × cm-1]
It follows for ethanol:
If the sample has been diluted during preparation, the result must be
multiplied by the dilution factor F.
When analyzing solid and semi-solid samples which are weighed out for
sample preparation, the result is to be calculated from the amount weighed:
Pipette into cuvettes Blank Sample
reaction mixture 2*
redist. water
sample solution**
3.000 ml
0.100 ml
-
3.000 ml
-
0.100 ml
Mix*** , after approx. 3 min read absorbances of the solutions (A1). Start reaction
by addition of:
suspension 3 0.050 ml 0.050 ml
Mix***, after completion of the reaction (approx. 5-10 min) read absorbances
of the solutions immediately one after another (A2).
A = (A2-A1)sample – (A2-A1)blank
c =
V × MG
× A [g/l]
ε × d × v × 2 ×1000
c =
3.150 × 46.07
× A =
0.7256
× A [g ethanol/l sample
ε × 1.00 × 0.100 × 2 ×1000 ε solution]
Contentethanol =
cethanol [g/l sample solution]
× 100 [g/100 g]
weightsample in g/l sample solution
0101.1. 668 559 SCC[
2
When analyzing ethanol containing samples (beverages, pharmaceuticals,
cosmetics), the alcoholic strength by volume at 20 °C is calculated by means
of the density of ethanol (at 20 °C) d = 0.789245:
cEthanol [g/l sample solution]
PercentageEthanol = [%; v/v]
10 x 0.78924 [g/ml]
1. Instructions for performance of assay
The amount of ethanol present in the assay has to be between 0.5 g and
12 g (measurement at 365 nm) or 0.3 g and 6 g (measurement at 340,
334 nm), respectively. In order to get a sufficient absorbance difference, the
sample solution is diluted to yield an ethanol concentration between 0.02
and 0.12 g/l or 0.01 and 0.06 g/l, respectively.
Because of the high sensitivity of the method it has to be taken care
that ethanol-free water is used and it is worked in an ethanol-free
atmosphere.
Dilution table
Because of the volatility of ethanol, the dilution of samples should be carried
out as follows:
Fill the volumetric flask approx. to the half with water (20°C) and pipette the
sample (20°C) with an enzyme test pipette or a piston type pipette under the
surface of the water. Fill up to the mark with water (20°C) and mix.
If the measured absorbance difference (ΔA) is too low (e.g. < 0.100), the
sample solution should be prepared again (weigh out more sample or dilute
less strongly) or the sample volume to be pipetted into the cuvette can be
increased up to 0.500 ml. The volume of solution 1 or reaction mixture 2,
respectively, remains the same (3.000 ml). The volume of water pipetted into
the blank assay must then be increased so as to obtain the same final
volume in the assays for sample and blank. The new sample volume (v) and
the new final volume (V) must be taken into account in the calculation.
2. Technical information
2.1. Ethanol is very volatile. Therefore it is necessary to be very careful when
handling ethanol containing samples, diluting samples and pipetting
sample solutions into the assay system.
When filtering solutions the filtrate should not drop into the container
but rinse down the wall.
When dispensing ethanol-containing solutions, always pipette these
solutions under the surface of water (when diluting) or of buffer (when
performing the assay).
2.2 When pipetting highly diluted sample solutions into the assay system,
rinse measuring glass pipette (enzyme test pipette) at least 6 times. The
tip of the piston type pipette should be rinsed 3 times.
2.3.Do not use the same piston type pipette for diluting the sample and
pipetting the sample solution into the assay system.
2.4. Always work in an alcohol-free atmosphere with ethanol-free water.
3. Specificity (Ref. 1)
The influence of aldehydes and ketones is eliminated by the order of reagent
addition during the assay. Methanol is not converted because of the
unfavourable Km-values of the enzymes used.
n-Propanol and n-butanol are quantitatively converted under assay
conditions, higher primary alcohols lead to sample-dependent creep
reactions. Secondary, tertiary and aromatic alcohols do not react. Even
higher concentrations of glycerol do not disturb the assay.
In the analysis of commercial ethanol results of approx. have to be
expected. (A recovery of less than does not mean an inclompete
conversion in the enzymatic reaction, it rather indicates the loss of ethanol
during the handling of the sample and preparing the sample solution, as
well as when pipetting the diluted ethanol solution into the assay system.)
Estimated amount of ethanol
per liter
measurement at
Dilution
with water
(in parts by
volume)
Dilution
factor F
340 or 334 nm 365 nm
 0.06 g
0.06-0.6 g
0.6-6.0 g
6.0-60 g
 60 g
< 0.12 g
0.12-1.2 g
1.2-12 g
12-120 g
 120 g
-
1 up to 10
1 up to 100
1 up to 1000
1 up to 10000
1
10
100
1000
10000
4. Sensitivity and detection limit (Ref. 1.3)
The smallest differentiating absorbance for the procedure is 0.005
absorbance units. This corresponds to a maximum sample volume v = 0.500 ml,
an assay volume V = 3.550 ml and measurement at 340 nm of an ethanol
concentration of approx. 0.1 mg/l sample solution (if v = 0.100 ml and
V = 3.150 ml, this corresponds to 0.6 mg/l sample solution).
The detection limit of 0.5 mg/l is derived from the absorbance difference of
0.020 (as measured at 340 nm), a maximum sample volume v = 0.500 ml and
an assay volume V = 3.550 ml.
5. Linearity
Linearity of the determination exists from approx. 0.3 g ethanol/assay
(0.5 mg ethanol/l sample solution; sample volume v = 0.500 ml; assay
volume V = 3.550 ml) to 12 g ethanol/assay (0.12 g ethanol/l sample
solution; sample volume v = 0.100 ml; assay volume V = 3.150 ml).
6. Precision
In a double determination using one sample solution, a difference of 0.005 to
0.010 absorbance units may occur. With a sample volume of v = 0.100 ml, an
assay volume of V = 3.150 ml and measurement at 340 nm, this corresponds
to an ethanol concentration of approx. 0.5-1 mg/l. (If the sample is diluted
during sample preparation, the result has to be multiplied by the dilution
factor F. If the sample is weighed in for sample preparation, e.g. using 1 g
sample/100 ml = 10 g/l, a difference of approx. 0.005-0.01 g/100 g can be
expected).
The following data have been published in the literature:
x = 2.5 g/assay CV = 1.2 % n = 16 in series
x = 5 g/assay CV = 0.56 % n = 16 in series
x =10 g/assay CV = 0.79 % n = 16 in series
x = 5 g/assay CV = 1.64 % n = 30 from day to day
(Ref. 1.2)
Lager beer x = 3.585 g/l r = 0.202 g/l s(r) = ± 0.071 g/l
R = 0.368 g/l s(R) = ± 0.130 g/l
Malt beer x = 4.755 g/l r = 0.243 g/l s(r) = ± 0.086 g/l
R = 0.591 g/l s(R) = ± 0.209 g/l
(Ref. 2.13)
For further data see references
7. Interference/sources of error
The presence of ethanol in the redist. water used for the assays or in air
results in increased blanks or in creep reactions, respectively. Therefore it is
necessary to cover the cuvette during the assay.
8. Recognizing interference during the assay procedure
8.1 If the conversion of ethanol has been completed according to the time
given under “Procedure“, it can be concluded in general that no
interference has occurred.
8.2 On completion of the reaction, the determination can be restarted by
adding ethanol (qualitative or quantitative): if the absorbance is altered
subsequent to the addition of the standard material, this is also an
indication that no interference has occurred.
8.3 Operator error or interference of the determination through the presence
of substances contained in the sample can be recognized by carrying
out a double determination using two different sample volumes
(e.g. 0.100 ml and 0.200 ml): the measured differences in absorbance
should be proportional to the sample volumes used for an identical final
volume.
When analyzing solid samples, it is recommended that different
quantities (e.g. 1 g and 2 g) be weighed into 100 ml volumetric flasks.
The absorbance differences measured and the weights of sample used
should be proportional for identical sample volumes.
8.4 Possible interference caused by substances contained in the sample can
be recognized by using an internal standard as a control: in addition to
the sample, blank and standard determinations, a further determination
should be carried out with sample and assay control solution in the
same assay. The recovery can then be calculated from the absorbance
differences measured.
8.5 Possible losses during the determination can be recognized by carrying
out recovery tests: the sample should be prepared and analyzed with
and without added standard material. The additive should be recovered
quantitatively within the error range of the method.
3
9. Reagent hazard
The reagents used in the determination of ethanol are not hazardous
materials in the sense of the Hazardous Substances Regulations, the
Chemicals Law or EC Regulation 67/548/EEC and subsequent alteration,
supplementation and adaption guidelines. However, the general safety
measures that apply to all chemical substances should be adhered to.
After use, the reagents can be disposed of with laboratory waste, but local
regulations must always be observed. Packaging material can be disposed
of in waste destined for recycling.
10. General information on sample preparation
In carrying out the assay:
Use clear, colorless and practically neutral liquid samples directly,
 or after dilution according to the dilution table (in order to avoid a loss of
ethanol, it is highly recommended to pipette the sample always under the
surface of the diluent), and of a volume up to 0.500 ml;
Filter turbid solutions (a loss of small amounts of ethanol is possible);
Degas samples containing carbon dioxide (e.g. by filtration, or in order to
avoid a loss of ethanol, by the addition of solid KOH or NaOH to bind CO2 as
bicarbonate);
Adjust acid samples to pH 8-9 by adding sodium or potassium hydroxide
solution;
Adjust acid and weekly colored samples to pH 8-9 by adding sodium or
potassium hydroxide solution and incubate for approx. 15 min;
Measure “colored” samples (if necessary adjusted to pH 8-9) against a
sample blank (= buffer or redist. water + sample), adjust the photometer to
0.000 with the blank in the beam;
Treat “strongly colored” samples that are used undiluted or with a higher
sample volume with polyamide or with polyvinylpolypyrrolidone (PVPP),
e.g. 2 g/100 ml;
Crush or homogenize solid or semi-solid samples, extract with water or
dissolve in water and filter if necessary; resp. remove turbidities or dyestuffs
by Carrez clarification;
Deproteinize samples containing protein with perchloric acid;
alternatively clarify with Carrez reagents;
Extract samples containing fat with hot water in a flask with a condenser
(extraction temperature should be above the melting point of the fat
involved). Cool to allow the fat to separate, rinse the condenser with redist.
water, make up to the mark, place the volumetric flask in an ice bath for
15 min and filter; alternatively clarify with Carrez-solutions after the
extraction with hot water.
Carrez clarification:
Pipette the liquid sample into a 100 ml volumetric flask which contains
approx. 60 ml redist. water, or weigh sufficient quantity of the sample into a
100 ml volumetric flask and add approx. 60 ml redist. water. Subsequently,
carefully add 5 ml Carrez-I-solution (potassium hexacyanoferrate(II) (ferrocyanide),
85 mM = 3.60 g K4[Fe(CN)6] × 3 H2O/100 ml) and 5 ml Carrez-IIsolution
(zinc sulfate, 250 mM = 7.20 g ZnSO4 × 7 H2O/100 ml). Adjust to pH
7.5-8.5 with sodium hydroxide (0.1 M; e.g. 10 ml). Mix after each addition. Fill
the volumetric flask to the mark, mix and filter.
11. Application examples
Determination of ethanol in fruit juices (Ref. 3.1, 2.6, 2.9, 2.12)
a) Use clear light-colored juices after neutralization or dilution, depending
on the ethanol content, for the assay (see dilution table).
b) Decolorize intensely colored juices by addition of 2% polyamide or
polyvinylpolypyrrolidone (PVPP) (e.g. 5 ml juice + 100 mg polyamide or
PVPP), stir for 2 min (vessel must be stoppered) and filter. Use the mostly
clear solution after neutralization for the assay. Decolorization can often
be omitted after dilution of the sample.
c) Filter turbid juices and clarify with Carrez-solutions, if necessary:
Pipette 10 ml of juice into a 25 ml volumetric flask, add 1.25 ml Carrez-Isolution
(3.60 g potassium hexacyanoferrate(II), K4[Fe(CN6)] × 3 H2O/100
ml), 1.25 ml Carrez-II-solution (7.20 g zinc sulfate, ZnSO4 × 7 H2O/100 ml)
and 2.50 ml NaOH (0.1 M), mix after each addition, fill up to 25 ml with
water, filter (dilution factor F = 2.5). Use the clear sample solution, which
may be weakly opalescent, for the assay directly or diluted, if necessary.
Determination of ethanol in low-alcohol and non-alcoholic beer
(Ref. 2.1, 2.10, 2.11, 2.13)
Add solid potassium hydroxide or solid sodium hydroxide to approx. 100 ml
sample in a beaker while stirring carefully until a pH value of approx. pH 8-9
is obtained. Use solution, diluted according to the dilution table, if necessary,
for the assay.
Determination of ethanol in vinegar
Filter, if necessary and neutralize vinegar. Neutralization can be omitted after
dilution of the sample.
Determination of ethanol in alcoholic beverages
a) Wine (Ref. 2.2, 2.8) Dilute wine with redist. water to the appropriate
concentration (see dilution table). Decolorization and neutralization are
not necessary.
b) Beer: To remove carbonic acid, stir approx. 5-10 ml of beer in a beaker for
approx. 30s using a glass rod or filter. Dilute the sample 1:1000 (1 + 999)
with water and use the diluted sample solution for the assay.
c) Liqueur: Pipette liquid liqueurs for dilution into an appropriate volumetric
flask and fill up to the mark with water.
Weigh approx. 1 g of viscous liqueurs (e.g. egg liqueur) accurately into a
100 ml volumetric flask, fill up to the mark with redist. water, mix, keep it
in a refrigerator for separation of fat, and filter.
Dilute the clear solution 1:100 (1 + 99) with water and use it for the assay.
Calculate result in g/100 g.
d) Brandy: Take care as mentioned when taking samples of alcoholic
beverages and dilute to a certain concentration (e.g. 1 + 9999 , e.g. in two
steps). Convert the measured values (g ethanol/l solution) into volume
percentage (v/v) with the aid of conversion tables, or the specific gravity
of ethanol5.
Determination of ethanol in chocolates, sweets and other alcoholcontaining
chocolate products
Chocolates with liquid filling compound (brandy balls, brandy cherries):
Open, e.g., one brandy ball carefully, pipette 0.500 ml of the liquid filling into
a 50 ml volumetric flask filled with approx. 25 ml water, taking care that the
tip of the pipette dips into the water. Fill up to the mark with water,
stopper and mix. Dilute the solution with water in a ratio of 1:20 (1 + 19).
Use 0.100 ml of the diluted solution for the assay (dilution factor F = 2000).
Chocolate products with highly viscous filling:
Accurately weigh the filling of one or several sweets or chocolates into a
50 ml volumetric flask filled with approx. 5 ml water (when the sample is
weighed by means of a pipette, the tip of the pipette must not touch the
water surface). Fill up to the mark with water, mix, filter, if necessary, and
dilute until the alcohol content of the sample is less than 0.12 g/l.
Determination of ethanol in jam (Ref. 2.7)
Homogenize sample thoroughly (mixer, etc.) and accurately weigh approx.
10-20 g into a beaker. Add some water, mix and neutralize the mixture with
KOH, if necessary. Transfer the mixture quantitatively into a 100 ml
volumetric flask and fill up to the mark with redist. water.
Decolorize solution with 2% polyamide or PVPP, if necessary (see pt. 10) and
filter. Use the filtrate for the assay undiluted.
Determination of ethanol in honey
Accurately weigh approx. 20 g honey into a 100 ml volumetric flask and
dissolve with some water under slight agitation at approx. 50°C (ascending
tube!), cool to 20°C and fill up to the mark with redist. water. Use the solution
for the assay, clarify with Carrez-solutions (see pt. 10), if necessary (dilution
factor F = 2.5). Use the clear solution for the assay after filtration.
Determination of ethanol in dairy products (e.g. curds, kefir)
Accurately weigh approx. 10 g of the homogenized sample into a 100 ml
volumetric flask, add approx. 50 ml water and keep the flask (ascending
tube!) at 50°C for 15 min under slight agitation. For protein precipitation add
5 ml Carrez-I-solution, 5 ml Carrez-II-solution and 10 ml NaOH (0.1 M)
(see pt. 10), mix after each addition. Allow to cool to 20°C and fill up to the
mark with water. Mix and filter. Use the clear, possibly slightly turbid solution
for the assay.
Determination of ethanol in protein-containing samples
Deproteinize protein-containing sample solutions with perchloric acid (1 M)
in a ratio of 1:3 (1+2) and centrifuge. Neutralize an aliquot of the supernatant
with KOH (2 M)
12. Further applications
The method may also be used in the examination of cosmetics (Ref. 3.3),
pharmaceuticals (Ref. 3.4), and in research when analyzing biological samples.
For details of sampling, treatment and stability of the sample see
Bernt, E. & Gutmann, I. (1974) in Methods of Enzymatic Analysis (Bergmeyer,
H. U., ed.) 2nd ed. vol. 3, p. 1500, Verlag Chemie, Weinheim/Academic Press.
Inc. New York and London.
Determination of ethanol in fermentation samples and cell culture
media
Place the sample (after centrifugation, if necessary) in a water-bath at 80°C
for 15 min (cover the tube because of the volatility of ethanol) to stop
enzymatic reactions. Centrifuge and use the supernatant (diluted according
to the dilution table, if necessary) for the assay. Alternatively, deproteinization
may be carried out with perchloric acid or with Carrez-solutions. See the
above-mentioned examples. Homogenize gelatinous agar media with water
and treat further as described.
4
Preparation
Dissolve 10 tablets from bottle 2 in 30 ml solution from bottle 1, add 0.5 ml
suspension from bottle 3, and mix.
(Note: Prepare reagent solution using alcohol-free redist. water in an
alcohol-free atmosphere. Store in a tightly stoppered container.)
Stability
The reagent solution is stable for 8 hours at 20°C
Sample preparation
Dilute beer, wine, brandy, and other samples that contain ethanol, according
to the dilution table.
The amount of ethanol present in the assay should range between 0.6 g
and 12 g. The sample solution must therefore be diluted sufficiently to yield
an ethanol concentration between 0.006 and 0.12 g/l
Due to the high sensitivity of the method care must be taken to use
ethanol-free water and to work in an ethanol-free atmosphere.
Dilution table
Because of the volatility of ethanol, the dilution of samples should be carried
out as follows:
Fill half of the volumetric flask with redist. water and pipette the sample
under the surface of water, using an enzyme test pipette or a piston type
pipette. Fill up to the mark with redist. water and mix.
References
1.1 Bücher, T. & Redetzki, H. (1951) Eine spezifische photometrische Bestimmung von Ethylalkohol
auf fermentativem Wege, Klinische Wochenschrift 29, 615-616
1.2 Beutler, H.-O. & Michal, G. (1977) Neue Methode zur enzymatischen Bestimmung von
Ethanol in Lebensmitteln, Z. Anal. Chem. 284, 113-117
1.3 Beutler, H.-O. (1984) in Methods of Enzymatic Analysis (Bergmeyer, H.U., ed.) 3rd ed.,
vol. VI, pp. 598-606, Verlag Chemie, Weinheim, Deerfield Beach/Florida,Basel
2.1 MONITEUR BELGE - BELGISCH STAATSBLAD: Bestimmung von Ethanol in alkoholarmen
Bier, S. 14610-14613 (26. September 1979)
2.2 Methodenbuch für Weinanalysen in Österreich (1980), herausgegeben von Arbeitsgemeinschaft
der Landw. Versuchsanstalten in Österreich (ALVA)
2.3 Schweizerisches Lebensmittelbuch, Kapitel 61B (Enzymatische Bestimmungen)/
2.1(1981), Kapitel 2B (Sauermilchprodukte)/22 (1980), Kapitel 9 (Speiseeis)/5.4 (1983),
Kapitel 28A (Frucht- und Gemüsesäfte, Fruchtnektare, Fruchtsirupe, Konzentrate und
Pulver/12.2 (1994), Kapitel 31 (Bier)/3.2 (1991), Kapitel 34 (Gärungsessig)/6.2 (1994)
2.4 Gombocz, E., Hellwig, E., Vojir, F. & Petuely, F. (1981) Deutsche Lebensmittel Rundschau 77, 8
2.5 Brautechnische Analysenmethoden, Band III, S. 550-553 (1982), Methodensammlung
der Mitteleuropäischen Brautechnischen Analysenkommission (MEBAK), herausgegeben
von F. Drawert im Selbstverlag der MEBAK, Freising
2.6 International Federation of Fruit Juice Producers (IFU, Methods of Analysis, no. 52-
1983); contained in "Code of Practice for Evaluation of Fruit and Vegetable Juices"
(1996) edited by Association of the Industry of Juices and Nectars from Fruits and Vegetables
of the European Economic Community (A.I.J.N.)
2.7 Österreichisches Lebensmittelbuch (Codex Alimentarius Austriacus), Kapitel B5
(Marmelade und andere Erzeugnisse), Erlaß vom 28. April 1985 (s. ERNÄHRUNG/
NUTRITION , 348-353 (1985); Kapitel B7 (Alkoholfreie natürliche Fruchtsäfte und
Fruchtgetränke) (1982)
2.8 The method is approved for official wine inspection in Rhenish-Palatinate (1985;
Chamber of Agriculture, Bad Kreuznach) and in Hesse (1986, Ministry for Agriculture
and Forestry).
2.9 Norme Française NF V 05-131 (Septembre 1986) Fruits, légumes et produits dérivés:
Détermination de la teneur en éthanol, Méthode enzymatique
2.10 Buckee, G.K. & Baker, C.D. (1986) Enzymatic Determination of Ethanol in Alcohol-Free
and Low Alcohol Beers, Monatsschrift für Brauwissenschaft 39, 257-259
2.11 European Brewery Convention, Analytica, 4th ed., Method 9.2, Ethanol in alcohol-free
and low alcohol beers, E153 (1987)
2.12 RSK-Values, The Complete Manual, Guide Values and Ranges of Specific Numbers for
Fruit Juices and Nectars, Including the Revised Methods of Analysis (1987), 1st ed.,
Verlag Flüssiges Obst/Liquid Fruit, D-56370 Eschborn, pp. 67-70
Estimated amount of
ethanol per liter
Dilution with water
(in parts by volume)
Dilution
factor F
6 - 120 g
> 120 g
1 up to 1000
1 up to 10000
1000
10000
Procedure
*) Note: Glass pipettes must be pre-rinsed with the (diluted) sample solution
at least 6 times, and the plastic tips of piston type pipettes 3 times. It
is also recommended to pipette the sample solution under the surface
of the reagent solution in the cuvette.
It is essential to stopper the cuvettes during measurement (see
"Instructions for performance of assay") e.g. with Parafilm (trademark
of American Can Company, Greenwich, Ct., USA) in order to
prevent the assay mixture form adsorption of ethanol form the air.
**) Pipetting of 0.100 ml redist. water is not necessary.
Calculation
Determine the absorbance differences (A2-A1) for both, blank and sample.
Subtract the absorbance difference of the blank from the absorbance
difference of the sample.
A = (A2 - A1)sample - (A2 - A1)blank
F = diluition factor
ε = extinction coefficient of NADH at:
340 nm = 6.30 [l × mmol-1 × cm-1]
Hg 365 nm = 3.40 [l × mmol-1 × cm-1]
Hg 334 nm = 6.18 [l × mmol-1 × cm-1]
cEthanol [g/l sample solution]
PercentageEthanol = [%; v/v]
10 x 0.78924 [g/ml]
2.13 Amtliche Sammlung von Untersuchungsverfahren nach 35 LMBG; Untersuchung von
Lebensmitteln: Bestimmung von Ethanol in Bier mit geringem Alkoholgehalt, 36.00-12
(Dezember 1992)
2.14 American Society of Brewing Chemists (1991) Enzymatic Method for Low Alcohol
Concentrations in Malt Beverages; ASBC Journal 49, 185-187
3.1 Tanner, H. & Brunner, E. M. (1965) Zur Bestimmung des in alkoholfreien Getränken und
in Aromadestillaten enthaltenen Ethylalkohols, Mitt. Gebiete Lebensm. Unters. u. Hyg. 56,
480-487
3.2 Quast, P. (1978) Weitere Notwendigkeiten und Möglichkeiten der Fruchtanalyse beim
Apfel, Mitt. Obstbauversuchsring des Alten Landes 9, 293-301
3.3 Henniger, G. & Boos, H. (1978) Anwendung der enzymatischen Analyse bei der
Untersuchung kosmetischer Präparate- dargestellt an einigen Beispielen, Seifen - Öle -
Fette - Wachse 104, 159-164
3.4 Henniger, G. & Hoch, H. (1981) Enzymatische Substratbestimmungen in der
pharmazeutischen Analytik, dargestellt an den Bestimmungen von L-Ascorbinsäure,
Ethanol und Lactose, Deutsche Apotheker Zeitung 121, 643-649
3.5 Kohler, P. (1982) Enzymatische Ethanol-Bestimmung in Glace- und Schokoladeprodukten,
Mitt. Gebiete Lebensm. Hyg. 73, 44-49
3.6 Pfandl, A. & Menschig, D. (1984) Ein Beitrag zur enzymatischen Glycerin- und Ethanolbestimmung,
Pharm. Ind. 46, 403-407
3.7 Plessi, M., Monzani, A., & Coppini, D. (1988) Determination of the Monosaccharide
and Alcohol Content of Balsamic and Other Vinegars by Enzymatic Methods,
Agric.Biol.Chem. 52, 25-30
3.8 Henniger, G. (1987) A Fast Enzymatic Method for the Determination of Ethanol in
Alcoholic Products, Poster-Präsentation bei Association of Official Analytical Chemists
Annual International Meeting, San Francisco, CA, USA
3.9 Würdig, G. & Woller, R. (1989) Chemie des Weines, Verlag Eugen Lehner, Stuttgart
3.10 Krüger, E. & Harms, J. (1995) Neue amtliche Methode zur Bestimmung von Ethanol in
Bier mit geringem Alkoholgehalt, Monatsschrift für Brauerei, 48, 160-161.
3.11 Rehbein, H. (1993) Assessment of fish spoilage by enzymatic determination of ethanol,
Archiv für Lebensmittelhygiene 44, 1-2
3.12 Huidobro, J.F., Rea, M.E., Branquinho de Andrade, P.C., Sanchez, M.P., Sanch, M.T.,
Muniategui, S. & Simal-Lozano, J. (1994) Enzymatic determination of primary normal
alcohols as apparant ethanol content in honey, J.Agric.Food Chem. 42, 1975-1978
3.13 Saalfeld, U. & Freund, W. (1998) Quantitative Ethanolbestimmung als Gärprüfverfahren
hefegelockerter Weizenteige, Deutsche Lebensmitttel-Rundschau 94, 292-296
Pipette into tubes Blank Sample
reagent solution 3.000 ml 3.000 ml
Read absorbances of the solutions (A1). Start reaction by the addition of:
diluted sample*) -**) 0.100 ml
Mix. After completion of the reaction (approx. 5-10 min) read absorbances of
the solutions immediately one after the other (A2).
c =
0.714
× A × F [g ethanol/l sample]
ε
13. Simplified procedure for the determination of ethanol in alcoholic beverages
and other samples containing at least 6 g ethanol/l
Concentration: see bottle label
Ethanol assay control solution is a stabilized aqueous solution of
ethanol. It serves as an assay control solution for the enzymatic
determination of ethanol in foodstuffs and other materials.
Application:
1. Addition of ethanol assay control solution to the assay mixture:
Instead of sample solution the assay control solution is used for the assay.
2. Restart of the reaction, quantitatively:
After completion of the reaction with sample solution and measuring of A2,
add 0.050 ml assay control solution to the assay mixture. Read absorbance
A3 after the end of the reaction (approx. 5 -10 min). Calculate the concentration
from the difference of (A3-A2) according to the general equation for
calculating the concentration. The altered total volume must be taken into
account. Because of the dilution of the assay mixture by addition of the
assay control solution, the result differs insignificantly from the data stated
on the bottle label.
3. Internal standard:
The assay control solution can be used as an internal standard in order to
check the determination for correct performance (gross errors) and to see
whether the sample solution is free from interfering substances:
The recovery of the standard is calculated according to the following
formula:
Pipette into
cuvettes
Blank Sample Standard Sample +
Standard
reaction mixture 2
redist. water
sample solution
assay control sln.
3.000 ml
0.100 ml
--
3.000 ml
-
0.100 ml
-
3.000 ml
--
0.100 ml
3.000 ml
-
0.050 ml
0.050 ml
Mix, and read absorbances of the solutions (A1) after approx. 3 min. Continue
as described in the pipetting scheme under "Procedure". Follow the instructions
given under "Instructions for performance of assay" and the footnotes.
recovery =
2 × Asample + standard - Asample × 100 [%]
Astandard
Ethanol assay control solution
R-BIOPHARM GmbH
Dolivostraße 10
64293 Darmstadt/Germany
Telefon + 49 61 51 / 81 02-0
Fax + 49 61 51 / 81 02-20

询价单